AHRS / Performance
ROBOR / PERFORMANCE DATA
iAHRS performance and specifications
Compare ROBOR iAHRS V2, V3 and V1 using defined performance criteria. Separate measured angle error, stationary variation, filter estimates and component specifications.
V2 and V3 have completed Korean KC registration. Naver Store pre-orders close on November 10, 2026, with dispatch scheduled from November 23 through November 27.
| Parameter | iAHRS-V2 NEW | iAHRS-V3 NEW | RB-SDA-v1 |
|---|---|---|---|
| Interface variant | USB + a choice of RS-232 / CAN / RS-485 | USB + a choice of RS-232 / CAN / RS-485 | USB + RS-232 |
| Serial output rate | Up to 100 Hz¹ | About 50 Hz / up to 100 Hz² | See model manual for output settings and fields |
| Attitude / heading error | Comparable test results not established | Comparable test results not established | Comparable test results not established |
¹ V2: configure for baud rate and enabled output fields. This is not the internal sensor sampling rate.
² V3: synchronous CSV gives about 50 Hz at 115200 bps and up to 100 Hz at 230400 bps or above.
V2 / V3 include USB: no suffix selects RS-232, _1 CAN, and _2 RS-485. The additional interface is model-specific. RB-OB-v1 is a separate board-level LV TTL UART product.
The current public documents do not establish a common-condition comparison of static and dynamic attitude and heading errors across the three models. Unconfirmed does not mean zero error or a missing function.
Read each performance metric separately
- Stationary output variation
- Variation while the sensor is held still. Specify standard deviation or peak-to-peak variation. This is different from error relative to a reference angle.
- Error relative to a reference
- Difference from a reference instrument. Separate static and dynamic tests and define the metric, such as RMS error or maximum absolute error.
- Filter-estimated 1σ
- According to the V2 / V3 manuals, the UI “accuracy” indication is calculated by the filter. It is not an externally measured error or a guaranteed product specification.
- Display increment
- The numerical step shown on the screen. A 0.01° display increment does not establish a 0.01° measurement error.
- Components and complete systems
- Sensor-chip noise density, measurement range and internal sampling rate are component specifications. Distinguish them from system angle error, usable range and communication output rate.
Conditions required for a meaningful comparison
Use the same test conditions and calculation method for every candidate. Published component figures, UI examples and stationary observations alone do not establish complete-system dynamic accuracy.
- Record the hardware model, firmware version, filter configuration and magnetic calibration.
- State temperature, mounting orientation, vibration, magnetic environment and warm-up time.
- Separate static and dynamic motion; identify the reference instrument and its uncertainty.
- Record output rate, duration and number of units, then define RMS error, maximum error or standard deviation.
- Keep measured typical values, guaranteed limits, filter estimates and component references in separate fields.
Detailed model information
Basis: ROBOR customer manuals, specification and performance sections, reviewed October 11, 2026. For performance comparisons, confirm model-specific test results and operating conditions.