AHRS / Performance

ROBOR / PERFORMANCE DATA

iAHRS performance and specifications

Compare ROBOR iAHRS V2, V3 and V1 using defined performance criteria. Separate measured angle error, stationary variation, filter estimates and component specifications.

Performance datasheet (English PDF) ↓Customer manuals and STEP CAD →

V2 and V3 have completed Korean KC registration. Naver Store pre-orders close on November 10, 2026, with dispatch scheduled from November 23 through November 27.

Sensor configuration and performance basis
ParameteriAHRS-V2 NEWiAHRS-V3 NEWRB-SDA-v1
Interface variantUSB + a choice of RS-232 / CAN / RS-485USB + a choice of RS-232 / CAN / RS-485USB + RS-232
Serial output rateUp to 100 Hz¹About 50 Hz / up to 100 Hz²See model manual for output settings and fields
Attitude / heading errorComparable test results not establishedComparable test results not establishedComparable test results not established

¹ V2: configure for baud rate and enabled output fields. This is not the internal sensor sampling rate.

² V3: synchronous CSV gives about 50 Hz at 115200 bps and up to 100 Hz at 230400 bps or above.

V2 / V3 include USB: no suffix selects RS-232, _1 CAN, and _2 RS-485. The additional interface is model-specific. RB-OB-v1 is a separate board-level LV TTL UART product.

The current public documents do not establish a common-condition comparison of static and dynamic attitude and heading errors across the three models. Unconfirmed does not mean zero error or a missing function.

Read each performance metric separately

Stationary output variation
Variation while the sensor is held still. Specify standard deviation or peak-to-peak variation. This is different from error relative to a reference angle.
Error relative to a reference
Difference from a reference instrument. Separate static and dynamic tests and define the metric, such as RMS error or maximum absolute error.
Filter-estimated 1σ
According to the V2 / V3 manuals, the UI “accuracy” indication is calculated by the filter. It is not an externally measured error or a guaranteed product specification.
Display increment
The numerical step shown on the screen. A 0.01° display increment does not establish a 0.01° measurement error.
Components and complete systems
Sensor-chip noise density, measurement range and internal sampling rate are component specifications. Distinguish them from system angle error, usable range and communication output rate.

Conditions required for a meaningful comparison

Use the same test conditions and calculation method for every candidate. Published component figures, UI examples and stationary observations alone do not establish complete-system dynamic accuracy.

Detailed model information

Basis: ROBOR customer manuals, specification and performance sections, reviewed October 11, 2026. For performance comparisons, confirm model-specific test results and operating conditions.