ROBOR / INTEGRATION

Troubleshoot connection and measurement symptoms

Start at the failing step and keep before-and-after conditions comparable.

USB device not detected

Check the data cable, power and another USB port. Identify the USB manufacturer and hardware ID in Device Manager, then install the driver for that chip. A CP210x driver does not apply to an FTDI device.

Cannot open the COM port

Close other monitors and terminals, then recheck the port number. Reconnecting a cable can change it. Record the selected port and exact error.

Connected but missing or corrupted data

Confirm the rate and frame format against the model manual and current settings. RS-232, LV TTL UART and RS-485 use different electrical interfaces. Check pinout, reference and adapters; do not connect them directly. First verify reception with the official application.

Unstable heading

Compare stopped/running motor conditions and distance from magnets, steel and current-carrying wires. Record mounting axes and calibration state. Calibration or filter changes cannot be assumed to remove every magnetic influence.

Firmware update error

Preserve the filename, model, current version and error for support. Bootloader changes, SWD programming and read-protection removal can erase data and are outside this troubleshooting procedure.

Prepare a support request

Include model, FW/UI versions, OS, interface/rate, power/wiring, reproduction steps, error screenshots and a short receive log. Send serial numbers through the dedicated inquiry form, not public posts.

Download integration checklist (PDF)
Download sensor quick guide (PDF)
Contact ROBORManuals and STEP files